Whitmer's Porta-Morgue

Home

Product / Faq Information

Models & Price, Warranty

Testimonials

Price List
Effective January 1, 2012
Specifications, Assembly
Warranty Plan
These units are not common, they are custom built condensing units.

*Lead Time*
Manufacturing 4-6 weeks.


Available Models
 
Model PM07
Standard Model
$4,514.60
* Standard Model *
Single Body Unit
Side Door Entry
Exterior Dimensions
39 5/8 inches W x 32 inches H x 95 inches L
Interior Dimensions
31 inches W x 24 inches H x 77 inches L
Embossed Galvalume (Exterior & Interior)
.080 Aluminum Floor w/ Coved Base
Weight 326 LBS.
Shipping Weight 500 LBS.

Model PM08
Stainless Steel
$5,925.34
Single Body Unit
Side Door Entry
Exterior Dimensions
39 5/8 inches W x 32 inches H x 95 inches L
Interior Dimensions
31 inches W x 24 inches H x 77 inches L
Stainless Steel (Exterior & Interior)
Stainless Steel Floor w/ Coved Base
Weight, Pending Information
Shipping Weight, Pending Information



Standard on all Models
9/16 inch.HEX Allen Wrench 
Four Carrying Handles
Solenoid Temperature Control
Thermostat
Door Latch/Lock
(New Side Door Lays on Top of Unit When Open)
115 Volt, 1/4 HP, Pre-Charged, Maintenance Free Compressor
Condensate Evaporator Pan in the Condensing Unit.
Cord & Three Prong Standard Plug
Warranty
1 Years Parts
5 Years Compressor
No Labor Warranty

Available Options

Model PM09
$4,514.60
Top Door available for use with body lift.

Model PM10
$4,404.39
Side or Top Glass Door for viewing of body.

12 Volt Power Inverters Available
Vehicle Transportation


220 Volt Step Down Too 110 Volt Converters Available
Overseas Usage

Crating Fee
Shipped By Truck Freight
$202.13

Materials, Labor & Insurance




Assembly

All units shipped assembled,

unless otherwise indicated.


Sequence of assembly.

Only 5 - 10 minutes to complete !

* Remove plug buttons in access holes on inside panels.*

*Turn wrench clock wise to lock cam locks.*

1. Lay bottom section on level surface, stand or cart.

2. Install left hand section using cam locks as shown.

3. Install rear section using cam locks.

4. Install right hand section w/ refrigeration unit using cam locks.

(Do not tip compressor more than 25 degrees.)

5. Lay top & attached door on and lock in place using cam locks.

* Back of unit should be against wall for safety.*

* Refrigeration unit should be ran for 15 to 20 minutes before use. *

 


Twelve (12) Month Limited Warranty Plan
One (1) Year Parts / Five (5) Years on Compressor
No Labor Warranty

Whitmer's PORTA-MORGUE warrants to the original purchase of the equipment,
that said equipment, including all parts thereof, is free from defects in material
and workmanship. PORTA-MORGUE's obligation under this warranty shall be
limited to repairing or exchanging any part or parts, F.O.B. Factory, which may
prove defective within one year from date of original shipment from the factory.
This warranty is in lieu of all other warranties, expressed or implied, and of all
obligations or liabilities on the part of PORTA-MORGUE, INCLUDING ANY
IMPLIED WARRANTY OF MERCHANTABILITY OF FITNESS,and it neither
assumes, nor authorizes any person to assume for it, any other obligation or
liability in connection with the sale of said equipment, or any part there of. This
Twelve (12) Month Warranty shall apply only within the boundaries of the
Continental United States.
 Certain restrictions may apply to the Twelve (12) Month Warranty.


 

 PORTA-MORGUE's, Company, Owner, Officers and Reps. not responsible for injury or death due  to incorrectly or improper use of the operation of the Porta-Morgue Unit, and/or its Compressor.

 PORTA-MORGUE, reserves the right to make changes in this product and/or literature at any time without notice. All Sales Final.


Prices and Specifications subject to change without notice.


Prepare for the Unexpected